Small Arteriovenous Anastomosis in Fistula Creation: Establishing a Functional Vascular Access while Minimizing Steal Syndrome

ANNALS OF VASCULAR SURGERY(2024)

引用 0|浏览3
暂无评分
摘要
Background: The size selection of the arteriovenous (AV) anastomosis in dialysis access creation requires a careful balance: the diameter must be large enough to accommodate sufficient flow for hemodialysis but small enough to minimize the complication of steal syndrome. Steal syndrome affects up to 10% of patients after creation of dialysis access with sometimes devastating consequences. Conventional teaching recommends a 7-10 mm anastomosis. We sought to assess the efficacy of using a smaller (5-6 mm) anastomosis in new arteriovenous fistula (AVF) creation.Methods: We conducted a comparative retrospective analysis of patients who underwent fistula creation with a small versus regular size anastomosis at any upper extremity anatomic site between March 2019 and October 2020 at our institution. Anatomic sites included radiocephalic, brachiocephalic, and brachiobasilic. All AV anastomoses were measured intraoperatively to be 5-6 mm in diameter for the small size groups and 8-10 mm for the regular size group. Endpoints included steal syndrome, functional patency, primary patency, and secondary patency.Results: Out of 110 patients who underwent an AVF creation, 59.1% received a 5-6 mm anastomosis with a median follow-up time of 10 +/- 6 months. Patients' demographics and comorbidities were relatively similar between the 2 groups except for a higher rate of hyperlipidemia (55.4% vs. 28.9%, P = 0.008) in the small size group. Patients in the small size group were more likely to undergo a radiocephalic fistula (40% vs. 4.5%, P < 0.001) and to have a smaller mean vein diameter on preoperative duplex ultrasound (3.2 +/- 1 mm vs. 3.9 +/- 1 mm, P = 0.0016) when compared to their regular size counterparts. During followup, none of the patients in the small group developed steal syndrome (0% vs. 9%, P = 0.015). At 1 year, patients in the regular size group achieved higher rates of primary patency (67.9% vs. 46.9%, P = 0.02); however, no difference was seen in 1-year primaryP = 0.3), or functional patency (87.7% vs. 82.2%, P = 0.64) between the small and regular size groups, respectively.Conclusions: The use of a 5-6 mm anastomosis in the creation of new AVFs of the upper extremities appears to be a technically safe option for dialysis access. Our experience suggests that smaller anastomosis still creates enough flow to maintain a functional AV access while minimizing the incidence of steal syndrome. Additionally, even with smaller vein sizes preoperative, adequate dialysis access can be created via a small sized anastomosis, including distal arm access. Larger studies with longer follow-up are needed to evaluate long-term outcomes of small anastomosis fistulas.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要