谷歌浏览器插件
订阅小程序
在清言上使用

178 Tumor neoantigen prioritization from liquid biopsy whole exome sequencing for selected tumor-infiltrating lymphocyte therapy

Journal for ImmunoTherapy of Cancer(2023)

引用 0|浏览14
暂无评分
摘要
BackgroundAdoptive cell transfer (ACT) of neoantigen-reactive tumor-infiltrating lymphocytes (TILs) is an emerging therapeutic modality for solid cancers. A growing body of clinical data in the TIL-ACT field supports the potential for the identification, selection, and expansion of tumor-reactive T cells to drive objective response in patients. We believe improvement in the method for identifying neoantigens may further increase the breadth and number of tumor-reactive T cells. Tissue biopsy based neoantigen identification can be limiting due to inter- and intra-tumoral heterogeneity and tissue access. Here, we applied whole exome DNA and RNA sequencing on patient liquid biopsy samples to assess the sensitivity of tumor variant detection and prioritization of neoantigen peptides in comparison with tissue data and to potentially improve target yield.MethodsMatched solid tissue and blood samples were collected from 10 patients (CRC, breast, melanoma, or NSCLC). For solid tissue, whole exome sequencing (WES) and transcriptome libraries were prepared using standard tissue protocols. For blood samples, cell-free DNA (cfDNA) and circulating RNA (cRNA) exome libraries were prepared using Illumina RUO library prep kit reagents. Solid tumor variant calling and neoantigen identification were performed by the Turnstone BFX-4101 platform. Liquid biopsy tumor variants and neoantigens were identified using the DRAGENTM Bio-IT platform and pVACtools suite.ResultsUltra-deep WES (>15,000x) of cfDNA resulted in 100% identification of known small variants at 0.5% variant allele frequency (VAF) in control samples, and >80% sensitivity for 0.2% VAF small variant detection in patient samples. Both analytical pipelines achieved 100% sensitivity on a dataset comprising experimentally determined immunogenic peptides. Concordance of somatic variant calls made between the solid and liquid biopsies ranged from 22%-88% concordance in 4 samples, while 6 samples showed no concordance. Further analysis showed a positive correlation between variant concordance and the percent tumor fraction in the liquid biopsy (from 3.6% to 0% tumor fraction in high to low concordance samples, respectively). For those samples with variant level concordance, up to 40% concordance was observed on neoepitope peptide identification between solid and liquid biopsies. In addition, the liquid biopsy data resulted in up to 29x more peptide calls than the solid tissue, suggesting the blood samples may contain unique tumor fragments not detected in solid tissue biopsy.ConclusionsMinimally invasive liquid biopsy is viable for detection of somatic variants with the potential to broaden selection of tumor-reactive TILs and improve objective response.AcknowledgementsAuthors U. Singh and C. Laing contributed equallyEthics ApprovalThis study was approved by the Advarra IRB; IRB#00000971; IRB#21.299. Informed consent was obtained from all participants.
更多
查看译文
关键词
tumor neoantigen prioritization,liquid biopsy,lymphocyte therapy,whole exome,tumor-infiltrating
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要