Multicenter interlaboratory study of routine systems for the susceptibility testing of temocillin using a challenge panel of multidrug-resistant strains

Corentin Deckers, Florian Bélik,Olivier Denis, Isabel Montesinos,Pierre Bogaerts, Jerina Boelens, Laetitia Brassinne,Julie Descy,Stefanie Desmet, Sarah Gils,Bénédicte Lissoir,Koen Magerman,Veerle Matheeussen,Cécile Meex, Hector Rodriguez Villalobos,Anne Marie Van den Abeele,Kris Vernelen,Pieter-Jan Ceyssens,Te-Din Huang, Jerina Boelens

European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology(2023)

引用 0|浏览13
暂无评分
摘要
Accurate susceptibility result of temocillin (TMO) is important for treating infections caused by multidrug-resistant Enterobacterales . This multicenter study aimed to investigate the performance of routine temocillin testing assays against Enterobacterales challenging strains. Forty-seven selected clinical isolates were blindly analyzed by 12 Belgian laboratories using VITEK® 2 ( n = 5) and BD Phoenix™ ( n = 3) automated systems, ETEST® gradient strip ( n = 3), and disk (3 brands) diffusion method (DD; n = 6) for temocillin susceptibility using standardized methodology. Results were interpreted using EUCAST 2023 criteria and compared to the broth microdilution (BMD; Sensititre™ panel) method used as gold standard. Methods’ reproducibility was assessed by testing 3 reference strains in triplicate. A total of 702 organism-drug results were obtained against 33 TMO-susceptible and 14 TMO-resistant isolates. Excluding Proteae species ( P. mirabilis and M. morganii) , the essential agreement rates were excellent (91.5–100%) for all MIC-based methods. The highest category agreement was achieved by ETEST® (97.5%) followed by VITEK® 2 (93.2%), disk diffusion (91.6%), and BD Phoenix™ (88.5%). BD Phoenix™ and paper disk diffusion overcalled resistance (11.5% and 6.8% of major discrepancies, respectively), while ROSCO tablets diffusion and VITEK® 2 generated higher very major discrepancies (7.1% and 4.2% respectively). Inter-assay reproducibility was unsatisfactory using recommended E. coli ATCC 25922 strain but was excellent with E. coli ATCC 35218 and K. pneumoniae ATCC 700603 strains. This interlaboratory study suggests that routine testing methods provide accurate and reproducible TMO categorization results except for Proteae species.
更多
查看译文
关键词
Temocillin,Antimicrobial susceptibility testing,Enterobacterales,EUCAST Breakpoints
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要