Impact on cerebral hemodynamics of the use of volume guarantee combined with high frequency oscillatory ventilation in a neonatal animal respiratory distress model

Alba Pérez-Pérez, Noelia González-Pacheco,María Arriaga-Redondo,Cristina Ramos-Navarro, Elena Rodríguez-Corrales, Ana Rodríguez-Sánchez de la Blanca, Pablo González-Navarro,Martín Santos-González,Manuel Sánchez-Luna

European Journal of Pediatrics(2024)

引用 0|浏览2
暂无评分
摘要
High-frequency oscillatory ventilation (HFOV) is an alternative to conventional mechanical ventilation (CMV). Recently, the use of volume guarantee (VG) combined with HFOV has been suggested as a safe strategy capable of reducing the damage induced by ventilation in immature lungs. However, the possible impact of this new ventilation technique on cerebral hemodynamics is unknown. To evaluate the cerebral hemodynamics effect of HFOV combined with VG in an experimental animal model of neonatal respiratory distress syndrome (RDS) due to surfactant deficiency compared with HFOV and CMV+VG (control group). Eighteen newborn piglets were randomized, before and after the induction of RDS by bronchoalveolar lavage, into 3 mechanical ventilation groups: CMV, HFOV and HFOV with VG. Changes in cerebral oxygen transport and consumption and cerebral blood flow were analyzed by non-invasive regional cerebral oxygen saturation (CrSO 2 ), jugular venous saturation (SjO 2 ), the calculated cerebral oxygen extraction fraction (COEF), the calculated cerebral fractional tissue oxygen extraction (cFTOE) and direct measurement of carotid artery flow. To analyze the temporal evolution of these variables, a mixed-effects linear regression model was constructed. After randomization, the following statistically significant results were found in every group: a drop in carotid artery flow: at a rate of -1.7 mL/kg/min (95% CI: -2.5 to -0.81; p < 0.001), CrSO 2 : at a rate of -6.2% (95% CI: -7.9 to -4.4; p < 0.001) and SjO 2 : at a rate of -20% (95% CI: -26 to -15; p < 0.001), accompanied by an increase in COEF: at a rate of 20% (95% CI: 15 to 26; p < 0.001) and cFTOE: at a rate of 0.07 (95% CI: 0.05 to 0.08; p < 0.001) in all groups. No statistically significant differences were found between the HFOV groups. Conclusion : No differences were observed at cerebral hemodynamic between respiratory assistance in HFOV with and without VG, being the latter ventilatory strategy equally safe. What is Known: • Preterm have a situation of fragility of cerebral perfusion wich means that any mechanical ventilation strategy can have a significant influence. High-frequency oscillatory ventilation (HFOV) is an alternative to conventional mechanical ventilation (CMV). Recently, the use of volume guarantee (VG) combined with HFOV has been suggested as a safe strategy capable of reducing the damage induced by ventilation in immature lungs. Several studies have compared CMV and HFOV and their effects at hemodynamic level. It is known that the use of high mean airway pressure in HFOV can cause an increase in pulmonary vascular resistance with a decrease in thoracic venous return. What is New: • The possible impact of VAFO + VG on cerebral hemodynamics is unknown. Due the lack of studies and the existing controversy, we have carried out this research project in an experimental animal model with the aim of evaluating the cerebral hemodynamic repercussion of the use of VG in HFOV compared to the classic strategy without VG.
更多
查看译文
关键词
Neonatal respiratory distress syndrome,High frequency ventilation,Volume guarantee,Cerebral blood flow,Near-infrared spectroscopy
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要