Weighted Filtered Back-Projection for Source Translation Computed Tomography Reconstruction.

IEEE Trans. Instrum. Meas.(2023)

引用 0|浏览13
暂无评分
摘要
Micro-computed tomography (micro-CT) is an indispensable tool to provide attenuation-based, high-resolution 3-D images in scientific research. However, its current available configuration limits the size of objects that can be imaged. Previously, we have proposed a multiple source translation computed tomography (mSTCT) imaging geometry to extend the field-of-view (FOV) of micro-CT, and developed a corresponding reconstruction algorithm called virtual projection-based filtered back-projection (V-FBP). V-FBP achieves high-resolution reconstructions when the source is densely sampled but fails if the source is coarsely sampled. In this article, to achieve high-resolution reconstruction at a low source sampling rate, we propose a full-scan multiple-STCT (F-mSTCT) scanning configuration, which allows for a simple and effective weighting function to deal with data redundancy and truncation simultaneously. Based on this concept, we develop a weighted FBP (W-FBP) algorithm. The numerical and physical experiments demonstrate that W-FBP is able to reconstruct high-resolution images at a low source sampling rate, and can reduce 1/2-3/4 projections compared with V-FBP at the same resolution.
更多
查看译文
关键词
Redundancy, Geometry, Detectors, Imaging, Image reconstruction, X-rays, Computed tomography, Filtered back-projection (FBP), high-resolution, multiple source translation computed tomography (mSTCT), truncation, weighting function
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要