Abstract
In the largest single institution series reported to date, we found unilateral adrenal SBRT to be safe, however, bilateral treatment harbors a risk of adrenal insufficiency. Dose per fraction ≥8 Gy was the most powerful predictor of local control, and a total dose ≥72gy and motion management were also significant. In conclusion, we propose a treatment regimen with a fraction size of at least 8 Gy and a total dosage of at least 72 Gy for evaluation, in a prospective clinical trial.