Consequences of different cut-off values for high-sensitivity cardiac troponin for risk stratification of patients suspected for NSTE-ACS with a modified HEART score.

Future cardiology(2023)

Cited 1|Views18
No score
Abstract
This study aims to enhance prehospital risk assessment for suspected non-ST-elevation acute coronary syndrome (NSTE-ACS) patients using the HEART-score. By incorporating novel point-of-care high-sensitivity cardiac troponin devices, a modified HEART-score was developed and compared with the conventional approach. Troponin points within the modified HEART-score are based on values below the limit of quantitation (LoQ), between the LoQ and 99th percentile and above the 99th percentile of the used device. A total HEART-score of three or lower is considered low-risk for major adverse cardiac events. The number of low-risk patients decreased based on the modified HEART-score. The sensitivity and negative predictive value increased which suggests increasing safety in ruling out patients with suspected NSTE-ACS.
More
Translated text
Key words
cardiac troponin,risk stratification,cut-off,high-sensitivity,nste-acs