Commissioning of the inductive heater for hypervapotron testing

FUSION ENGINEERING AND DESIGN(2023)

Cited 0|Views3
No score
Abstract
The paper describes commissioning of the inductive heater based on numerical simulation of inductive heating in the hypervapotron sample and test channel. The HEFEL loop is being developed to research a high heat flux cooling channels applicable in fusion devices. The Box Scraper hypervapotron channel geometry represents a primary focus of research. Conditions in the first wall of tokamak are simulated by induction heating of the tested hypervapotron channel. The exact heat flux of tested sample is difficult to measure, thus the numerical simulation of induction heating and thermohydraulic model of the cooling channel are an important part of HEFEL loop commissioning. ANSYS Maxwell 3D and ANSYS Fluent coupling is used for optimalization of the induction heating to achieve the highest heat fluxes using selected induction heating source.
More
Translated text
Key words
Hypervapotron,High heat flux cooling,ANSYS maxwell,ANSYS fluent
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined