Detection of limited-energy particles using CR-39 in laser-induced p-11B reaction

FRONTIERS IN PHYSICS(2023)

引用 0|浏览19
暂无评分
摘要
Due to the harsh radiation environment produced by strong laser plasma, most of the detectors based on semiconductors cannot perform well. So, it is important to develop new detecting techniques with higher detection thresholds and highly charged particle resolution for investigating nuclear fusion reactions in laser-plasma environments. The Columbia Resin No. 39 (CR-39) detector is mainly sensitive to ions and insensitive to the backgrounds, such as electrons and photons. The detector has been widely used to detect charged particles in laser-plasma environments. In this work, we used a potassium-ethanol-water (PEW) etching solution to reduce the proton sensitivity of CR-39, by raising the detection threshold for the research of laser-induced (11) B(p, a)2a reaction. We calibrated the 3-5 MeV a particles in an etching condition of 60? PEW-25 solution (17% KOH + 25%C2H5OH + 58%H2O) and compared them with the manufacturer's recommended etching conditions of 6.25 N NaOH aqueous solution at 98? in our laser-induced nuclear reaction experiment. The results indicate, with the PEW-25 solution, that CR-39 is more suitable to distinguish a tracks from the proton background in our experiment. We also present a method to estimate the minimum detection range of a energy on specific etching conditions in our experiment.
更多
查看译文
关键词
CR-39, PEW solution, proton boron fusion, laser-induced fusion, track detector
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要