Does the AVNeo valve reduce wall stress on the aortic wall? A cardiac magnetic resonance analysis with 4D-flow for the evaluation of aortic valve replacement with the Ozaki technique

EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY(2023)

Cited 0|Views12
No score
Abstract
OBJECTIVES Aortic valve neocuspidalization aims to replace the 3 aortic cusps with autologous pericardium pre-treated with glutaraldehyde, and it is a surgical alternative to the classical aortic valve replacement (AVR). Image-based patient-specific computational fluid dynamics allows the derivation of shear stress on the aortic wall [wall shear stress (WSS)]. Previous studies support a potential link between increased WSS and histological alterations of the aortic wall. The aim of this study is to compare the WSS of the ascending aorta in patients undergoing aortic valve neocuspidalization versus AVR with biological prostheses.METHODS This is a prospective nonrandomized clinical trial. Each patient underwent a 4D-flow cardiac magnetic resonance scan after surgery, which informed patient-specific computational fluid dynamics models to evaluate WSS at the ascending aortic wall. The adjusted variables were calculated by summing the residuals obtained from a multivariate linear model (with ejection fraction and left ventricle outflow tract-aorta angle as covariates) to the mean of the variables.RESULTS Ten patients treated with aortic valve neocuspidalization were enrolled and compared with 10 AVR patients. The aortic valve neocuspidalization group showed a significantly lower WSS in the outer curvature segments of the proximal and distal ascending aorta as compared to AVR patients (P = 0.0179 and 0.0412, respectively). WSS levels remained significantly lower along the outer curvature of the proximal aorta in the aortic valve neocuspidalization population, even after adjusting the WSS for the ejection fraction and the left ventricle outflow tract-aorta angle [2.44 Pa (2.17-3.01) vs 1.94 Pa (1.72-2.01), P = 0.02].CONCLUSIONS Aortic valve neocuspidalization hemodynamical features are potentially associated with a lower WSS in the ascending aorta as compared to commercially available bioprosthetic valves. Aortic valve replacement (AVR) with prosthesis is the treatment of choice for aortic valve disease.
More
Translated text
Key words
Av-neocuspidalization,Wall shear stress,Aortic valve pathology
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined