Chrome Extension
WeChat Mini Program
Use on ChatGLM

Uncertainty-aware spot rejection rate as quality metric for proton therapy using a digital tracking calorimeter

Alexander Schilling, Max Aehle, Johan Alme, Gergely Gabor Barnafoeldi, Tea Bodova, Vyacheslav Borshchov, Anthony van den Brink, Viljar Eikeland, Gregory Feofilov, Christoph Garth, Nicolas R. Gauger, Ola Grottvik, Havard Helstrup, Sergey Igolkin, Ralf Keidel, Chinorat Kobdaj, Tobias Kortus, Viktor Leonhardt, Shruti Mehendale, Raju Ningappa Mulawade, Odd Harald Odland, George O'Neill, Gabor Papp, Thomas Peitzmann, Helge Egil Seime Pettersen, Pierluigi Piersimoni, Maksym Protsenko, Max Rauch, Attiq Ur Rehman, Matthias Richter, Dieter Roehrich, Joshua Santana, Joao Seco, Arnon Songmoolnak, Akos Sudar, Ganesh Tambave, Ihor Tymchuk, Kjetil Ullaland, Monika Varga-Kofarago, Lennart Volz, Boris Wagner, Steffen Wendzel, Alexander Wiebel,Renzheng Xiao, Shiming Yang, Sebastian Zillien

Physics in medicine and biology(2023)

Cited 0|Views21
No score
Abstract
Objective. Proton therapy is highly sensitive to range uncertainties due to the nature of the dose deposition of charged particles. To ensure treatment quality, range verification methods can be used to verify that the individual spots in a pencil beam scanning treatment fraction match the treatment plan. This study introduces a novel metric for proton therapy quality control based on uncertainties in range verification of individual spots. Approach. We employ uncertainty-aware deep neural networks to predict the Bragg peak depth in an anthropomorphic phantom based on secondary charged particle detection in a silicon pixel telescope designed for proton computed tomography. The subsequently predicted Bragg peak positions, along with their uncertainties, are compared to the treatment plan, rejecting spots which are predicted to be outside the 95% confidence interval. The such-produced spot rejection rate presents a metric for the quality of the treatment fraction. Main results. The introduced spot rejection rate metric is shown to be well-defined for range predictors with well-calibrated uncertainties. Using this method, treatment errors in the form of lateral shifts can be detected down to 1 mm after around 1400 treated spots with spot intensities of 1 x 107 protons. The range verification model used in this metric predicts the Bragg peak depth to a mean absolute error of 1.107 & PLUSMN; 0.015 mm. Significance. Uncertainty-aware machine learning has potential applications in proton therapy quality control. This work presents the foundation for future developments in this area.
More
Translated text
Key words
machine learning,particle therapy,range verification,uncertainty
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined