Contrast-enhanced US with Sulfur Hexafluoride and Perfluorobutane: LI-RADS for Diagnosing Hepatocellular Carcinoma

RADIOLOGY(2023)

Cited 0|Views22
No score
Abstract
Background: Liver Imaging Reporting and Data System (LI-RADS) was designed for contrast-enhanced US (CEUS) with pure blood pool agents to diagnose hepatocellularfcarcinoma (HCC), such as sulfur hexafluoride (SHF), but Kupffer-cell agents, such as perfluorobutane (PFB), allow additional lesion characterization in the Kupffer phase yet remain unaddressed. Purpose: To compare the diagnostic performance of three algorithms for HCC diagnosis: two algorithms based on CEUS LI-RADS version 2017 for both SHF and PFB and a modified algorithm incorporating Kupffer-phase findings for PFB. Materials and Methods: This multicenter prospective study enrolled high-risk patients for HCC from June 2021 to December 2021. Each participant underwent same-day SHF-enhanced US followed by PFB-enhanced US. Each liver observation was assigned three LI-RADS categories according to each algorithm: LI-RADS SHF, LI-RADS PFB, and modified PFB. For modified PFB, observations at least 10 mm with nonrim arterial phase hyperenhancement were upgraded LR-4 to LR-5 if there was no washout with a Kupffer defect and were reassigned LR-M to LR-5 if there was early washout with mild Kupffer defect. The reference standard was pathologic confirmation or composite (typical CT or MRI features, or 1-year size stability and/or reduction). Diagnostic metrics of LR-5 for HCC using the three algorithms were calculated and compared using the McNemar test. Results: Overall, 375 patients (mean age, 56 years +/- 11 [SD]; 318 male patients, 57 female patients) with 424 observations (345 HCCs, 40 non-HCC malignancies, 39 benign lesions) were enrolled. PFB and SHF both using LI-RADS showed no significant difference in sensitivity (60% vs 58%; P =.41) and specificity (96% vs 95%; P >.99). The modified algorithm with PFB had increased sensitivity (80% vs 58%; P <.001) and a nonsignificant decrease in specificity (92% vs 95%; P =.73) compared with LI-RADS SHF. Conclusion: Based on CEUS LI-RADS version 2017, both SHF and PFB achieved high specificity and relatively low sensitivity for HCC diagnosis. When incorporating Kupffer-phase findings, PFB had higher sensitivity without loss of specificity. Chinese Clinical Trial Registry no. ChiCTR2100047035 (c) RSNA, 2023
More
Translated text
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined