摘要
This work presents a system for measuring and analyzing motion, by a portable electronic device and a flexible fiber sensor. The fiber is composed of multi-walled carbon nanotubes (MWCNTs) for its conductivity and polydimethylsiloxane elastomer (PDMS) for its elasticity. A new sensor interface circuit was designed in this study to interface with the fiber and measure its impedance. The measured impedance data are sampled and transmitted via Bluetooth to a laptop. The characteristics of the fiber and a wireless measurement system allow an easy integration into a smart garment to monitor various vital signs and motion markers (e.g angle, step). The system was assessed on a robotic arm before being put in realistic situations through various exercises (flexion/extension knee movements, standing multi-joint movements and walk/run on treadmill) on 5 participants for its ability to measure angle, number of movements, rate and speed. In addition, fibers measurement endurance capacities over months were observed. An assessment of the fiber impedance measurement circuit was performed (minimum resolution of $25~\Omega $ , relative error of 2.82% on the estimated value of resistance). Tests carried out over a period of several months show that the fiber maintained good measurement performance when tested on a robotic arm, given an average correlation of 0.85 between angle and fiber impedance. The relative error (RE) made on the number of detected movements was 6.57% in average. In realistic workout situations, these values respectively reached between 0.58 and 73.95% for flexion/extension knee movements. A correlation factor of 0.76 was obtained when the participants were walking on a treadmill at a given speed. Otherwise, RE on number of movements was 8.33% for treadmill exercise, 12.84% on standing exercise. For these exercises and for the movement rate, the average correlation calculated with the reference was between 0.75 and 0.33. Finally, RE on estimated speed was 23.3% in average for the treadmill exercise. The system (sensor interface circuit and Fiber) allows to properly monitor human motion in various activities.
更多
查看译文
关键词
Wearable sensors, biomedical instrumentation, conductive and stretchable fiber, MWCNTs, PDMS, impedance measurement circuit, motion detection, stride rate, velocity
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要