Synergistic Piezo-Catalytic Inactivation of Bacteria by Dual-Frequency Ultrasound (120 + 1700 kHz) Using Persulfate and ZnO Nano- and Microparticles

Water(2023)

Cited 0|Views4
No score
Abstract
Dual-frequency ultrasound (DFUS) coupled with sonocatalysts has emerged to be an advanced tool for antimicrobial applications in medicine but remains scarcely studied for water disinfection. In the present work, we first integrated high-frequency DFUS (120 + 1700 kHz), persulfate (S2O82−) and ZnO nano- (50 nm) and microparticles (1 μm) for eradicating Escherichia coli and Enterococcus faecalis in synthetic water. For E. coli, the efficiency of DFUS-based processes can be ranked as follows: DFUS < DFUS/ZnO < DFUS/S2O82− < DFUS/ZnO/S2O82−. A similar efficiency of the DFUS/S2O82− and DFUS/ZnO/S2O82− processes was found for more resistant E. faecalis. In the absence of persulfate, the performance of 1 μm ZnO was higher than that observed with 50 nm for inactivating E. coli via the DFUS/ZnO and 1700 kHz/ZnO processes. A synergy of DFUS in terms of 5-log (total) reduction was found in the S2O82−/ZnO-based systems, being higher for E. faecalis (synergistic coefficient = 1.8–3.0). The synergistic effect was proposed to be driven by the boosted generation of reactive oxygen species and sonoporation. This study opens prospects for the development of novel DFUS-based piezo-catalytic systems for efficient water disinfection.
More
Translated text
Key words
ultrasound,piezo-catalytic,dual-frequency
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined