Using Mitra sampling to support first-in-human pharmacokinetic evaluations for PF-07059013.

Kimberly C Lee,Katty X Wan,Jason Barricklow, Chay Ngee Lim, Stephen Clarke,Daniel Potts, Kevin Holmes,Pilar Gonzalez,Olga Kavetska

Bioanalysis(2023)

引用 0|浏览1
暂无评分
摘要
A sensitive and selective method for the determination of PF-07059013 in dried blood collected by Mitra™ tips was developed and qualified from 50 to 50,000 ng/ml. PF-07059013 is isolated from 10 μl of human dried blood by extraction with methanol and analyzed by HPLC-MS/MS. In addition to routine validation elements, impact of hematocrit and Mitra tip's lot-to-lot variation on assay accuracy were evaluated. The qualified method was used in one clinical study with excellent performance. Correlation coefficient between blood concentrations obtained from liquid-incurred blood samples and dried-incurred blood samples is 0.95. NCT04323124 (ClinicalTrials.gov).
更多
查看译文
关键词
assay concordance, dried blood, LC-MS/MS, microsampling, Mitra, qualification