Correlation between Accuracy in Computer-Guided Implantology and Peri-Implant Tissue Stability: A Prospective Clinical and Radiological Pilot Study.

Journal of clinical medicine(2023)

Cited 0|Views4
No score
Abstract
The present pilot study was designed by hypothesizing a possible correlation between lack of accuracy in implant placement and peri-implant hard and soft tissue health. A total of five patients underwent computer-guided implant surgery and full-arch immediate loading between 2013 and 2014. They subsequently underwent postoperative cone-beam computed tomography (CBCT). After a follow-up of 5 years, all patients were recalled for a clinical-radiographic evaluation of peri-implant health status. The mean linear deviation was 0.5 ± 0.2 mm at the implant's head and 0.6 ± 0.2 mm at the implant's apex, while the mean angular deviation of the long axis was 2.8° ± 1.2°. A mean marginal bone loss (MBL) of 1.16 ± 0.94 mm and 2.01 ± 1.76 mm was observed after 1 and 5 years of follow-up, respectively. At 5 years, the mean peri-implant probing depth (PPD) was 4.09 ± 1.44 mm, 66.6% of the evaluated implants showed peri-implant bleeding on probing (BOP), keratinized mucosa (KM) was <2 mm in 48.4% of cases, and mucosal recession (REC) ≥ 1 mm was assessed in 45.4% of the included implants. A negative correlation was observed between bucco-palatal/lingual linear inaccuracy and MBL, PPD, BOP, and KM.
More
Translated text
Key words
computer-guided implantology, dental implants, digital dentistry, peri-implant hard tissue, peri-implant health, peri-implant soft tissue
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined