Abstract
This work studied the wind load acting on a point focus solar furnace composed of a 110 m(2) heliostat and a 77 m(2) concentrator through wind tunnel testing. Based on wind tunnel test data under 305 different working conditions, the variation laws of the wind pressure coefficient, power spectral density, and wind load coefficient of the heliostat and concentrator were analyzed. The results showed that due to the interaction between the concentrator and heliostat, the wind speed near the heliostat and concentrator decreased but the turbulence intensity increased, which caused the peak wind load coefficient to rise slightly. The results suggested that a safety factor of 1.1-1.2 should be considered for structural design and optimization of solar furnaces.
MoreTranslated text
Key words
point focus solar furnace,heliostat,concentrator,wind load,wind tunnel test