Implementation of sogi-pll algorithm for single phase grid connected inverters based on fixed-point arithmetic

INTERNATIONAL JOURNAL OF INNOVATIVE COMPUTING INFORMATION AND CONTROL(2023)

引用 0|浏览0
暂无评分
摘要
. The tracking performance of a phase-locked loop (PLL) algorithm in gridconnected power electronic systems significantly contributes to the success of grid synchronization. This paper presents an efficient software realization of SOGI-PLL (second order generalized integrator - phase locked loop), as one of the most popular single-phase grid synchronization strategies in practice. The utilization of floating-point processors has been relatively common; however in this work, the SOGI-PLL is implemented using the fixed-point arithmetic technique in consideration of delivering a low-cost and compact hardware solution. Fixed-point microcontrollers or DSPs are still widely used by many researchers, developers, and practical engineers due to their cost-efficient implementation in both hardware and development software tools. In this work, the implementation of the SOGI-PLL algorithm in fixed-point arithmetic is demonstrated using C programming in a low-cost 16-bit fixed-point DSC dsPIC30F3014 with a 20 MHz crystal clock. Based on the implementation results, the developed SOGI-PLL algorithm can accurately estimate the grid's fundamental voltage parameters such as the voltage magnitude, phase angle, and frequency.
更多
查看译文
关键词
Fixed-point arithmetic, Grid-connected inverter, SOGI-PLL, Single-phase grid, Synchronization