Radiographic comparison of eccentric stemmed versus concentric stemless prosthetic humeral head positioning after anatomic total shoulder arthroplasty.

Journal of shoulder and elbow surgery(2023)

Cited 0|Views3
No score
Abstract
Stemless and stemmed aTSA implants have similar rates of reproducing satisfactory postoperative humeral head COR with both producing COR deviation most commonly in the superomedial direction. Deviation in HHH contributes to overstuffing in both stemmed and stemless implants, COR deviation contributes to overstuffing in stemmed implants, while RoC (humeral head size) is not associated with overstuffing. Based on this study, it appears that neither eccentric nor concentric prosthetic heads are superior in recreating premorbid humeral head position.