Dosimetry impact of distinct gating strategies in cine MR image-guided breath-hold pancreatic cancer radiotherapy.

Journal of applied clinical medical physics(2023)

引用 0|浏览1
暂无评分
摘要
In tumor contour-based gating strategy, the dose delivery accuracy deteriorates while the dose delivery efficiency improves with increasing gating thresholds. To ensure treatment efficiency, the gating threshold might be no less than 3%. A threshold up to 5% may be acceptable in terms of the GTV coverage. The displacement-based gating strategy may serve as a potential alternative to the tumor contour based gating strategy, in which the gating threshold of approximately 4 mm might be a good choice for reasonably balancing the dose delivery accuracy and efficiency.
更多
查看译文
关键词
breath hold, cine MRI, gating strategies, pancreatic cancer