Technical Validation of Ultrasound Assessment of the Thyroid Gland in Cattle.

Veterinary sciences(2023)

引用 0|浏览6
暂无评分
摘要
Little is known about thyroid diseases in ruminants, probably due to the lack of diagnosis techniques developed in this species. However, thyroid ultrasound (TU) is widely used in human and in companion animal's medicine. It is a cheap and non-invasive examination, which allows for the identification of thyroid structures or diffuse diseases. The aim of this study was to evaluate the accuracy of TU in five calves and five cows through inter- and intra-observer repeatability. The size of the thyroid gland was measured from three views: left sagittal, right sagittal and transverse; nine measurements per view. The intra-observer coefficient was calculated for each observer. For the inter-observer, the first observer was a board-certified imagist (European College of Veterinary Diagnostic Imaging diplomate), the second was a board-certified specialist in bovine and herd management (European College of Bovine Health Managementdiplomate) and the third was an in-trained veterinarian for the TU. They each scanned the thyroid gland successively, following the same method. The intra-observer variabilities for observers 1, 2 and 3 were 8.22%, 5.53%, 5.38%, and 7.18%, 8.65% and 6.36%, respectively, for calves and cows. The inter-observer variability for calves was 10.4% and for cows, 11.8%. This study confirms the feasibility of repeatable intra- and inter-observer TU-estimated measurements in cattle.
更多
查看译文
关键词
cattle, ultrasonography, diagnostic imaging, metabolism, endocrine system
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要