Percutaneous Recanalization of Interrupted Aortic Arch Using Laser Atherectomy

JACC-CARDIOVASCULAR INTERVENTIONS(2023)

Cited 0|Views3
No score
Abstract
Data regarding the impact of high transcatheter heart valve (THV) implantation on coronary access after transcatheter aortic valve replacement (TAVR) as assessed by postimplantation computed tomography (CT) are scarce.The authors sought to assess the impact of high THV implantation on coronary access after TAVR.We included 160 and 258 patients treated with Evolut R/PRO/PRO+ and SAPIEN 3 THVs, respectively. In the Evolut R/PRO/PRO+ group, the target implantation depth was 1 to 3 mm using the cusp overlap view with commissural alignment technique for the high implantation technique (HIT), whereas it was 3 to 5 mm using 3-cusp coplanar view for the conventional implantation technique (CIT). In the SAPIEN 3 group, the HIT employed the radiolucent line-guided implantation, whereas the central balloon marker-guided implantation was used for the CIT. Post-TAVR CT was performed to analyze coronary accessibility.HIT reduced the incidence of new conduction disturbances after TAVR for both THVs. In the Evolut R/PRO/PRO+ group, post-TAVR CT showed that the HIT group had a higher incidence of the interference of THV skirt (22.0% vs 9.1%; P = 0.03) and a lower incidence of the interference of THV commissural posts (26.0% vs 42.7%; P = 0.04) with access to 1 or both coronary ostia compared with the CIT group. These incidences were similar between the HIT and CIT groups in the SAPIEN 3 group (THV skirt: 0.9% vs 0.7%; P = 1.00; THV commissural tabs: 15.7% vs 15.3%; P = 0.93). In both THVs, CT-identified risk of sinus sequestration in TAVR-in-TAVR was significantly higher in the HIT group compared with the CIT group (Evolut R/PRO/PRO+ group: 64.0% vs 41.8%; P = 0.009; SAPIEN 3 group: 17.6% vs 5.3%; P = 0.002).High THV implantation substantially reduced conduction disturbances after TAVR. However, post-TAVR CT revealed that there is a risk for unfavorable future coronary access after TAVR and sinus sequestration in TAVR-in-TAVR. (Impact of High Implantation of Transcatheter Heart Valve during Transcatheter Aortic Valve Replacement on Future Coronary Access; UMIN000048336)
More
Translated text
Key words
coarctation of aorta,interrupted aortic arch,laser atherectomy
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined