Implementing 3D fluoroscopy in the management of tibial plateau fractures: Shorter hospitalization and decline in revision surgery, but increase in the duration of surgery and radiation exposure.

Roos J M Havermans, Eline Stroobants, Martin de Kiefte, Stijn D Nelen, Mike Bemelman,Koen W W Lansink

Injury(2023)

Cited 1|Views3
No score
Abstract
Implementing 3DRX in treating TFs improves the assessment of fracture alignment and implant position perioperatively, resulting in more intraoperative corrections and no revision surgeries within 6 weeks postoperatively. However, using 3DRX significantly increases perioperative radiation exposure and surgery duration without a significant rise in postoperative infections and a shorter hospital length of stay.
More
Translated text
Key words
3D Fluoroscopy, Perioperative imaging, Tibial plateau fractures, Radiation exposure, Revision surgery