Failure of an ASTM A213 T12 steel tube of a circulating fluidized bed boiler

Engineering Failure Analysis(2023)

引用 0|浏览5
暂无评分
摘要
•Localized bulging was observed in a section of the outermost tube of the superheater.•Severe degradation of the microstructure was evidenced in the bulging region.•A weld defect affected the steam flow and local heat transfer.•The heterogeneous flue gas flow induced localized overheating of the tube.•The failure was related to a conjunction of long time overheating and creep.
更多
查看译文
关键词
Circulating fluidized bed boiler,Manufacturing weld defect,Creep fracture,UNS K11562,Ferritic steel
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper