A simultaneous CH4 and CO2 flux quantification method for industrial site emissions from in-situ concentration measurements on-board an Unmanned Aircraft Vehicle

Jean-Louis Bonne, Ludovic Donnat, Grégory Albora, Jérémie Burgalat,Nicolas Chauvin, Delphine Combaz, Julien Cousin, Thomas Decarpenterie,Olivier Duclaux,Nicolas Dumelié, Nicolas Galas,Catherine Juery, Florian Parent, Florent Pineau, Abel Maunoury, Olivier Ventre, Marie-France Bénassy,Lilian Joly

crossref(2023)

引用 0|浏览0
暂无评分
摘要
Abstract. We developed an innovative tool to quantify CO2 and CH4 emissions at the scale of an industrial site, based on a mass balance approach relying on a newly developed light-weight (1.4 kg) open path laser absorption spectrometer operable on-board Unmanned Aircraft Vehicles (UAVs). This spectrometer simultaneously records in situ CO2 and CH4 concentrations at high frequency (24 Hz in this study) with precisions of 10 ppb for CH4 and 1 ppm for CO2 averaged at 1 Hz. The large range of measurable concentrations, up to 1000 ppm for CO2 and 200 ppm for CH4, makes this analyzer suitable for operation on industrial sites at a short distance from the emission sources, therefore avoiding many logistical and legal limits associated with most long-range airborne observations. To quantify the emissions, high spatial resolution atmospheric concentration measurements obtained throughout a plume cross-section downwind of a source within the limited UAV flight period are exploited by calculations using a mass balance approach. This high spatial resolution, allowed by the high acquisition frequency, limits the use of horizontal interpolation, thus gaining in precision compared to current airborne alternative quantification techniques. A field validation campaign, conducted on the TotalEnergies TADI test platform at Lacq, France, consisted in controlled CO2 and CH4 leak experiments to which several institutes participated with various measurement systems (gas LiDAR, multispectral camera, infrared camera including concentrations and emissions quantification system, acoustic sensors, ground mobile and fixed Cavity RingDown Spectrometers). Our method was proved suitable to detect leaks during controlled release experiments with emission fluxes down to 0.01 g s−1, with 24 % of estimated CH4 fluxes within the −20 % to +20 % error range, 80 % of quantifications within the −50 % to +100 % error range and all of our results within the −69 % to +150 % error range. Such precision levels are better ranked than current top-down alternative techniques to quantify CH4 at comparable spatial scales. Observations across the plume of two offshore oil and gas platforms operated by TotalEnergies in the North Sea were used to quantify the instantaneous greenhouse gases emissions of these facilities and are coherent with reference emissions for these platforms estimated by mass balance and combustion calculations for CO2. The operational deployment of such instruments and quantification methods, on a large scale and on a regular basis, potentially with fully autonomous UAVs, will allow the quantification of the time dependent greenhouse gases emissions of numerous oil and gas facilities.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要