Abstract WMP49: Occult Contrast Retention Post-thrombectomy On 24-hour Follow-up CT: Associations And Impact On Imaging Analysis

Stroke(2023)

引用 0|浏览15
暂无评分
摘要
Introduction: CT performed 24h post-treatment is widely used to assess radiological outcomes in stroke studies. Even without visible hyperattenuation, occult angiographic contrast may persist in the brain and confound Hounsfield Unit-based imaging metrics such as Net Water Uptake (NWU), a measure of cerebral edema based on tissue hypoattenuation. We aimed to assess (1) the presence of retained contrast post-thrombectomy on 24h CT by comparing NWU measurements with and without adjustment for iodine using dual energy CT (DECT), (2) factors associated with amount of retention, and (3) its impact on the accuracy of NWU. Methods: In a prospective study of patients with anterior circulation large vessel occlusion who had post-thrombectomy follow-up DECT performed 24h post-treatment from two Comprehensive Stroke Centres (November 2021 to May 2022), NWU was calculated by interside comparison of Hounsfield Units of the infarct lesion and its mirror homolog. Retained contrast was quantified by the difference in NWU values with and without adjustment for iodine. We tested correlation between NWU and tissue swelling using relative hemispheric volume (rHV) and midline shift (MLS). Patients with visible hyperdensities from hemorrhagic transformation or visible contrast retention, and bilateral infarcts were excluded. Results: Of 125 patients analysed (median age 71 [IQR 61-80], baseline NIHSS 16 [IQR 9.75-21]), reperfusion (eTICI 2b-3) was achieved in 120 patients (96.8%). NWU measured with iodine adjustment was significantly higher than NWU measured without adjustment (17.1% vs 10.8%, p<0.001). In multivariable median regression analysis, age (p=0.031), number of passes (p<0.001) and having CT perfusion at baseline (p=0.008) were independently associated with amount of retained contrast. NWU measured with iodine adjustment correlated with rHV (p=0.043) and MLS (p=0.033), but NWU without adjustment did not (rHV p=0.350; MLS p=0.347). Conclusion: Occult angiographic iodine contrast significantly affects NWU on CT at 24h. Our data suggest adjustment for retained iodine using DECT is required for accurate NWU measures post-thrombectomy. Future studies analysing CT post-thrombectomy should consider the significance of occult contrast retention.
更多
查看译文
关键词
abstract wmp49,imaging analysis,post-thrombectomy
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要