Background Patients with lower-limb osteomyelitis (LLOM) may experience major adverse events, such as lower-leg amputations or death; therefore, early diagnosis and risk stratification are essential to improve outcomes. Ga-scintigraphy is commonly used for diagnosing inflammatory diseases. Although the diagnostic performance of planar and SPECT imaging for localized lesions is limited, SPECT/CT, which simultaneously acquires functional and anatomical definition, has resulted in significant improvements to diagnostic confidence. While quantitative Ga-SPECT/CT is an emerging approach to improve diagnoses, its diagnostic performance has not been sufficiently evaluated to date. Therefore, this study aimed to evaluate the diagnostic performance of Ga-SPECT/CT with quantitative analyses for patients with LLOM. Methods A total of 103 consecutive patients suspected of LLOM between April 2012 and October 2016 were analyzed. All patients underwent Ga-scintigraphy with SPECT/CT imaging. Findings were assessed visually, with higher than background accumulation considered positive, and quantitatively, using Ga-SPECT/CT images to calculate the lesion-to-background ratio (LBR), the maximum standardized uptake value (SUVmax), and total lesion uptake (TLU). Diagnoses were confirmed using pathological examinations and patient outcomes, and diagnostic performances of planar, SPECT, and SPECT/CT images were compared. To evaluate prognostic performance, all patients were observed for 5 years for occurrences of major adverse events (MAE), defined as recurrence of osteomyelitis, major leg amputation, or fatal event. Multivariate Cox regression was performed to evaluate outcome factors. Results The overall diagnoses indicated that 54 out of 103 patients had LLOM. LBR, SUVmax, and TLU were significantly higher in patients with LLOM (12.23 vs. 1.00, 4.85 vs. 1.34, and 68.77 vs. 8.63, respectively; p < 0.001). Sensitivity and specificity were 91% and 96% for SPECT/CT with LBR, 89% and 94% for SPECT/CT with SUVmax, and 91% and 92% for SPECT/CT with TLU, respectively. MAE occurred in 23 of 54 LLOM patients (43%). TLU was found to be an independent prognostic factor ( p = 0.047). Conclusions Ga-SPECT/CT using quantitative parameters, namely LBR and TLU, had better diagnostic and prognostic performances for patients with LLOM compared to conventional imaging. The results suggest that Ga-SPECT/CT is a good alternative for diagnosing LLOM in countries where FDG-PET/CT is not commonly available.
更多
查看译文
关键词
SPECT/CT, Quantitative analysis, Osteomyelitis, Diagnostic performance, Prognostic value
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要