This paper describes research into the poorly understood axial behaviour of piles driven in chalk. Comprehensive dynamic and monotonic axial testing on 27, mostly instrumented, piles undertaken for the ALPACA Joint Industry Projects is reported and interpreted covering: diameters between 139mm and 1.8m; lengths from 3 to 18m; different pile material types; tip and groundwater conditions, and ages after driving. The experiments show the factors that influence resistance most strongly are: (i) pile end-conditions, (ii) slenderness ratio and flexibility, (iii) shaft material, (iv) age after driving, (vi) relative water table depth, and (vii) whether loading is compressive or tensile. Varying the factors systematically identified a remarkable average long-term shaft resistance range from below 11 kPa to more than 200 kPa for piles driven at the same low-to-medium density chalk test site in Kent (UK). Dynamic and static analyses demonstrate that soil resistances to driving (SRD) were generally well-predicted by the Chalk ICP-18 short-term formulation. Considering the piles’ long-term behaviour, the Chalk ICP-18 approach over-predicted capacity, while the widely used CIRIA approach proved over-conservative for most cases. The research enabled the development of a revised ‘ALPACA-SNW’ long-term capacity assessment method that matches the test outcomes far more faithfully.
更多
查看译文
关键词
axial capacity, chalk, driven pile, fibre Bragg grating (FBG) sensors, field tests, time dependence