#5918 endovascular creation of an arteriovenous fistula (endoavf) for hemodialysis access: a retrospective monocentric experience

Nephrology Dialysis Transplantation(2023)

Cited 0|Views4
No score
Abstract
Abstract Background and Aims Functioning vascular access is an essential element for life-saving hemodialysis therapy. Surgical creation of a radiocephalic arteriovenous fistula (AVF) is the gold standard of vascular access for hemodialysis. However an endovascular approach to arteriovenous fistula creation (endoAVF) has increasingly gained acceptance over the last years as an alternative to the conventional surgical method. It offers a minimally invasive method for the formation of arteriovenous shunts and allows the creation of fistulas with minimal vessel trauma. There are currently two technologies available for this purpose, the Ellipsys Vascular Access System (Medtronic, Avenu Medical, San Juan Capistrano, Calif) and the Wavelinq endoAVF System (BD Medical, Franklin Lakes, NJ). At our centre (Careggi University Hospital, Florence), we developed an integrated service, based on a multidisciplinary approach between Interventional Radiology and Interventional Nephrology for percutaneous arteriovenous fistulas utilizing both Ellipsys and Wavelinq. We describe our experience with a case series of 39 patients, showing feasibility and outcome of this treatment option. Method Between December 2020 and January 2023 we created an endoAVF in 39 patients. Patients were suitable for the procedure after a pre-therapeutic ultrasound vascular mapping showed adequate brachial, radial and ulnar vessels and no ipsilateral central venous stenosis. After procedure, we performed a regular clinical and ultrasound monitoring. Therefore, we collected data regarding patient characteristics, initial technical success rate, number of access lost and number of endoAVF meeting primary and secondary patency. Results Of the total of 39 patients treated with endoAVF, 29 (74.3%) were male, with a mean age of 60.1 ± 33.9 years. The Wavelinq procedure was performed in 32 patients (82.0%) and the Ellipsys procedure in 7 patients (17.9%). Initial technical success was achieved in 38 (97.4%) cases, while in 1 case we had a primary failure of the fistula (Figure 1). Among these 38 patients, 4 (10.5%) were lost to follow-up because of death from other causes (3 patients) and because of kidney transplantation (1 patient), while 2 other patients (5.2%) have not required hemodialysys yet. Of the remaining 32 patients, we had 2 fistulas lost because of complications and a cumulative functional patency of 93.7% (30 fistulas), with a primary patency rate of 76% (23 fistulas). Conclusion The endoAVF appears to be feasible and safe for the creation of arteriovenous fistula suitable for hemodialysis access. Our data show an high functional cumulative patency of the endoAVF and a good primary patency, reducing the necessity of further interventions. Furthermore, in the prevalent hemodialysis population, the minimally invasive endovascular arteriovenous fistula procedure should help improving long wait times for vascular access creation. Further studies with more patients and multicentric data are needed to assess long-term outcomes.
More
Translated text
Key words
arteriovenous fistula,hemodialysis access,endovascular creation,endoavf
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined