Failure analysis of a tandem mill ring gear
Engineering Failure Analysis(2023)
Abstract
•The roll end ring gear failed due to corrosion fatigue.•Cracks nucleated from corrosion pits on the outer surface of the component.•The corrosion mechanism was differential aeration corrosion due to sludge deposits.•This was possibly aided by microbiologically influenced corrosion.
MoreTranslated text
Key words
failure analysis
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined