Abstract
•The roll end ring gear failed due to corrosion fatigue.•Cracks nucleated from corrosion pits on the outer surface of the component.•The corrosion mechanism was differential aeration corrosion due to sludge deposits.•This was possibly aided by microbiologically influenced corrosion.