We report on the development of a system called velocimetry by actively stabilized coherent optical transfer (VASCOT) that uses active optical phase tracking to measure the in-line velocity of retroreflect-ing targets with narrow-band photodetection. VASCOT is experimentally demonstrated over a 584-m atmospheric link to a corner-cube retroreflector (CCR) on an airborne drone. The in-line target-velocity measurement achieves residual uncertainties below 2 nm s-1 within 5 s of averaging. Cycle-slip-free phase tracking over the full 3-min experiment allows the relative target range to be tracked with a one-standard -deviation uncertainty of 39.5 nm. VASCOT also provides an absolute target-range measurement with a statistical error of +/- 13.7 mm, which agrees with an independent Global-Positioning -System-(GPS) derived range measurement to within the GPS uncertainty.