Research on Dynamic Performance of Independent Metering Valves Controlling Concrete-Placing Booms Based on Fuzzy-LADRC Controller

Actuators(2023)

引用 2|浏览1
暂无评分
摘要
Motion control of truck-mounted concrete pump booms is an important part of concrete construction work. The quality of the boom movement will affect the efficiency and safety of construction operations. To make the boom move quickly and steadily, its hydraulic control system needs to be improved. In this article, we firstly combine independent metering control (IMC) and active disturbance rejection control (ADRC). The hydraulic system that controls the boom is meliorated by replacing the traditional proportional directional spool valve with four cartridge flow control valves to realize IMC. Meanwhile, a fuzzy linear ADRC algorithm is proposed for a new IMC hydraulic system where ADRC is linearized and combined with fuzzy logic to achieve better motion control performance of boom sections. According to the results of experiments conducted using all six boom sections, compared with the PID control algorithm, the fuzzy linear active disturbance rejection control (FLADRC) proposed in this article can improve the stability and rapidity of valves controlled by hydraulic cylinders by 10.0% to 66.7% in different working conditions.
更多
查看译文
关键词
independent metering valves, fuzzy logic, LADRC, electro-hydraulic boom system