Effect of Spring-Mass-Damper Pedestrian Models on the Performance of Low-Frequency or Lightweight Glazed Floors

APPLIED SCIENCES-BASEL(2023)

引用 0|浏览1
暂无评分
摘要
For structural design purposes, human-induced loads on pedestrian systems can be described by several simplified (i.e., deterministic equivalent-force models) or more complex computational approaches. Among others, the Spring-Mass-Damper (SMD), Single Degree of Freedom (SDOF) model has been elaborated by several researchers to describe single pedestrians (or groups) in the form of equivalent body mass m, spring stiffness k and damping coefficient c. For all these literature SMD formulations, it is proved that the biodynamic features of walking pedestrians can be realistically reproduced, with high computational efficiency for vibration serviceability assessment of those pedestrian systems mostly sensitive to human-induced loads (i.e., with vibration frequency f(1) < 8 Hz). Besides, the same SMD proposals are characterized by mostly different theoretical and experimental assumptions for calibration. On the practical side, strongly different SMD input parameters can thus be obtained for a given pedestrian. This paper focuses on a selection of literature on SMD models, especially on their dynamic effects on different structural floor systems. Four different floors are explored (F#1 and F#2 made of concrete, F#3 and F#4 of glass), with high- or low-frequency, and/or high- (>1/130th) or low- (1/4th) mass ratio, compared to the occupant. Normal walking scenarios with frequency in the range f(p) = 1.5-2 Hz are taken into account for a total of 100 dynamic simulations. The quantitative comparison of typical structural performance indicators for vibration serviceability assessment (i.e., acceleration peak, RMS, CREST) shows significant sensitivity to input SMD assumptions. Most importantly, the sensitivity of structural behaviours is observed for low-frequency systems, as expected, but also for low-mass structures, which (as in the case of glazed floor solutions) can be characterized by the use of lightweight modular units with relatively high vibration frequency. As such, major attention can be required for their vibrational analysis and assessment.
更多
查看译文
关键词
human-induced effects,pedestrian structures,Spring-Mass-Damper (SMD) models,Single Degree of Freedom (SDOF) model,numerical analysis,structural performance indicators
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要