Examining 7 years of implementing quality management systems in medical laboratories in sub-Saharan Africa

Collins O. O. Odhiambo, Beatrice van Der Puije, Michael Maina,Teferi Mekonen, Samba Diallo,Tjeerd Datema,Marguerite M. M. Loembe,Yenew Kebede, Nqobile Ndlovu,Pascale Ondoa

TROPICAL MEDICINE & INTERNATIONAL HEALTH(2023)

引用 1|浏览0
暂无评分
摘要
BackgroundAchievement of ISO15189 accreditation demonstrates competency of a laboratory to conduct testing. Three programmes were developed to facilitate achievement of accreditation in low- and middle-income countries: Strengthening Laboratory Management Towards Accreditation (SLMTA), Stepwise Laboratory Improvement Process Towards Accreditation (SLIPTA) and Laboratory Quality Stepwise Implementation (LQSI).ObjectiveTo determine the level of accreditation and associated barriers and facilitators among medical laboratories in the WHO-AFRO region by 2020.MethodsA desk review of SLIPTA and SLMTA databases was conducted to identify ISO15189-accredited medical laboratories between January 2013 and December 2020. Data on access to the LQSI tool were extracted from the WHO database. Facility and country characteristics were collected for analysis as possible enablers of accreditation. The chi-square test was used to analyse differences with level of significance set at < 0.05.ResultsA total of 668 laboratories achieved accreditation by 2020 representing a 75% increase from the number in 2013. Accredited laboratories were mainly in South Africa (n = 396; 55%) and Kenya (n = 106; 16%), two countries with national accreditation bodies. About 16.9% (n = 113) of the accredited laboratories were registered for the SLIPTA programme and 26.6% (n = 178) for SLMTA. Approximately 58,217 LQSI users were registered by December 2020. Countries with a higher UHC index for access to HIV care and treatment, higher WHO JEE scores for laboratory networks, a larger number of registered LQSI users, with national laboratory policy/strategic plans and PEPFAR-priority countries were more likely to have an accredited laboratory. Of the 475 laboratories engaged in the SLIPTA programme, 154 attained & GE;4 SLIPTA stars (ready to apply for accreditation) and 113 achieved ISO 15189 accreditation, with 96 enrolled into the SLMTA programme. Lower-tier laboratories were less likely to achieve accreditation than higher-tier laboratories (7.7% vs. 30%) (p < 0.001). The probability of achieving ISO 15189 accreditation (19%) was highest during the first 24 months after enrolment into the SLIPTA programme.ConclusionTo sustainably anchor quality improvement initiatives at facility level, national approaches including access to a national accreditation authority, adoption of national quality standards and regulatory frameworks are required.
更多
查看译文
关键词
accreditation, ISO15189, quality assurance, quality management system, SLIPTA, SLMTA
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要