Bacterial Assessment of Stethoscopes Used by Healthcare Workers at a Tertiary Care Government Hospital in Bharatpur, Nepal.

Sanjib Adhikari,Neetu Adhikaree,Krishna Prasad Paudel, Roshan Nepal, Birendra Poudel, Sujan Giri, Suman Khadka, Saphala Khawas,Sanjeep Sapkota,Ramesh Sharma Regmi,Komal Raj Rijal

Diseases (Basel, Switzerland)(2023)

引用 0|浏览3
暂无评分
摘要
The transmission of healthcare-associated infections (HCAIs) in healthcare settings is a serious challenge in the medical fraternity. Medical devices, such as stethoscopes used by healthcare workers (HCWs), are likely to harbor a considerable number of pathogenic microbes, which may result in the transmission of HCAIs. This study sought to investigate bacterial contamination of stethoscopes used by HCWs at Bharatpur Hospital, Nepal. During the study period of 3 months from December 2019 to February 2020, a total of 87 stethoscopes were examined; bacterial pathogens were isolated and identified by culture and biochemical tests, and their susceptibilities against different antibiotics were determined using standard protocols of the Clinical and Laboratory Standards Institute (CLSI). The disc diffusion method was used primarily to screen for extended-spectrum beta-lactamase (ESBL)- and metallo-beta-lactamase (MBL)-producing isolates, followed by their confirmation using cephalosporin/clavulanate combination discs and the disc potentiation methods, respectively. In addition, molecular detection of and genes was performed using conventional polymerase chain reaction (PCR). Of the 87 stethoscopes examined, more than a quarter (28.7%) were colonized with different pathogenic bacteria. Bacterial contamination of stethoscopes was found to be significantly associated with various factors, such as disinfecting routine, method of disinfection, and department of the hospital ( < 0.05). A higher rate of bacterial contamination was observed on the diaphragm of the stethoscope (12.64%) and among HCWs who overlooked hand hygiene practices (45.45%). The prevalence of methicillin-resistant (MRSA) was 44.44%, and approximately half of the Gram-negative isolates (47%) were multidrug resistant (MDR). Imipenem (81.25%) and chloramphenicol (83.33%) were found to be the most effective antibiotics for Gram-negative and Gram-positive bacteria, respectively. Phenotypic screening showed that 43.75% of isolates were ESBL producers, and 18.75% were MBL producers, but and genes were detected in only 31.25% and 6.25% of isolates, respectively. The results of the study call for effective stethoscope disinfection practices along with the judicious use of antibiotics by HCWs in order to minimize cross-contamination, emergence of resistance, and spread of nosocomial infections in clinical settings.
更多
查看译文
关键词
ESBL,MBL,healthcare workers,nosocomial infection,stethoscope
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要