Chrome Extension
WeChat Mini Program
Use on ChatGLM

Primary Cooperative Application of a LARS (R) Tube and 3D-Printed Prosthesis for Reconstruction of the Distal Radius after en bloc Resection of Giant Cell Tumor of Bone: A Comparative Retrospective Study

Orthopaedic surgery(2023)

Cited 0|Views10
No score
Abstract
ObjectiveUsing a fibula autograft (FA) to reconstruct defects after en bloc resection of giant cell tumor of bone (GCTB) in the distal radius is classic but has high complication rates. We describe a novel reconstruction method employing the cooperative application of LARS (R) and a 3D-printed prosthesis (L-P) and investigate whether it improves postoperative outcomes. MethodsFrom April 2015 to August 2022, 14 patients who underwent the cooperative L-P reconstruction method after en bloc resection of distal radial GCTBs and 31 patients who received FA reconstruction were enrolled as two retrospective cohorts in this comparative study. The properties of the implants and critical surgical techniques were elaborated in the L-P group. Preoperative function, intraoperative data, and postoperative clinical, functional, and radiographic outcomes of all patients were recorded and compared between the two groups. The grip strength and range of wrist motion, including extension, flexion, radial deviation, and ulnar deviation, were measured. The Mayo modified wrist and Musculoskeletal Tumor Society scores were chosen to assess wrist function and surgical functional outcomes, respectively. Kaplan-Meier curves were generated to analyze the significant differences in complication rates and implant survival between the two groups. ResultsIn both groups, all 45 patients underwent the operation without complication with similar average osteotomy lengths and bleeding volumes, while a shorter operative duration was achieved in the L-P group (201.43 +/- 22.87 min vs. 230.16 +/- 51.44 min, P = 0.015). At a mean follow-up of 40.42 +/- 18.43 months (range, 14-72 months), both reconstruction methods effectively ameliorated postoperative function. Patients who received L-P showed higher postoperative modified Mayo wrist scores (81.43 +/- 5.49 vs. 71.13 +/- 16.10, P = 0.003), Musculoskeletal Tumor Society scores (27.64 +/- 1.34 vs. 25.06 +/- 2.95, P = 0.004), and grip strength on the normal side (68.71% +/- 8.00% vs. 57.81% +/- 12.31%, P = 0.005) than the FA group. Better wrist extension (63.21 degrees +/- 8.99 degrees vs. 45.32 degrees +/- 14.53 degrees, P < 0.001) and flexion (45.36 degrees +/- 7.90 degrees vs. 30.48 degrees +/- 12.07 degrees, P < 0.001) were also observed in the L-P group. The complication rate was significantly higher in the FA group (29/31, 93.55%) than in the L-P group (1/14 7.14%, P < 0.001). The L-P group showed higher implant survival than the FA group, but the difference was not statistically significant. ConclusionThe cooperative application of LARS (R) and 3D-printed prostheses is an effective modality for reconstructing musculoskeletal defects after en bloc resection of distal radial GCTBs, which can improve functional outcomes, diminish complication rates, and promote wrist joint stability and motion.
More
Translated text
Key words
3D-printed prosthesis,Distal radius,Fibula autograft,Giant cell tumor of bone,Ligament advanced reinforcement system
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined