Limitations of transthoracic echocardiography in equine patients.

Veterinary medicine and science(2023)

引用 0|浏览3
暂无评分
摘要
Transthoracic echocardiography (TTE) is part of every comprehensive cardiac examination in horses (Schwarzwald, 2019). However, the echocardiographic assessment of cardiac structures, chamber dimensions, and myocardial function is challenging and limited by a variety of technical, anatomic, and physiological factors that need to be considered (Vitale et al., 2021). More recently, transesophageal and three-dimensional echocardiography have been described to overcome some of the limitations of the two-dimensional traditional echocardiography, nevertheless they are not widely available in equine hospitals (Schwarzwald, 2018). During the ultrasonographic examination, the valves are inspected for the number and morphology of the leaflets and cusps, the integrity of the support apparatus and motion during the cardiac cycle (Marr, 2019). In the recently published article (Vitale et al., 2021), the authors described a 4-year-old Thoroughbred with mild aortic regurgitation suspected to be due to a quadricuspid aortic valve, a form of aortic valve dysplasia. Valvular dysplasia refers to a valve that is malformed, which may manifest as stenosis, insufficiency, or both (Scansen, 2019). The case presented in the article was referred to the hospital because of the development of paroxysmal atrial fibrillation, and on interrogation with colour flow Doppler, mild aortic and pulmonary regurgitation was identified. These mild regurgitations are unlikely to affect performance or to result in any clinical signs (Reef et al., 2014). Nevertheless, as described in the article, the authors repeatedly obtained images of the aortic valve, which were thought to be abnormal. This clinical commentary arises from the same authors because deeper examination of the recorded images and video loops of that echocardiography, and together with the opinion of a clinician with more experience in cardiology (GvL), indicated that this interpretation was most likely wrong. Indeed, while reviewing the recordings, in diastole, with the valve completely closed, it was possible to obtain static images that are in fact incompatible with a quadricuspid aortic valve (Figure 1). Although at the time of the article submission and publication, the authors genuinely believed that there was a likelihood of four cusps, with this clinical commentary they provide the readers with an update. Because static images are difficult to interpret, video loops are included to better evaluate the case presented (Videos S1 and S2). As already mentioned in the original paper (Vitale et al., 2021), when dealing with concave/convex structures in rapid movement, such as the cardiac valves, a slight off-angle section plane can produce an artefactual image resembling more subdivided cusps (Figures 2 and 3). For the aortic valve, this typically occurs in diastole on a short axis view that is taken slightly too ventrally. On such a view, one can easily be misled by the images obtained. This error further supports the conclusion of the article regarding the difficulties and risks of misdiagnosis that transthoracic echocardiography includes (Malik et al., 2017; Orde et al., 2017). The lessons learned and the advice to other clinicians are as follows: 1) to be extremely careful in the evaluation of potentially abnormal structures during echocardiography; 2) to obtain contemporaneous electrocardiographic recordings with the ultrasound machine in order to correctly identify the timepoint within the cardiac cycle; and 3) to re-evaluate stored video loops offline and in slow motion in case of any doubts and/or perform advanced cardiac imaging (3D or intracardiac ultrasound). Writing–original draft: Valentina Vitale. Investigation: Malene Laurberg. Writing–review and editing: Gaby Van Galen. Project administration and writing–review and editing: Gunther van Loon. No ethical statement has been uploaded as no animals have been used in this commentary article. The peer review history for this article is available at https://publons.com/publon/10.1002/vms3.906. Data sharing not applicable to this article as no datasets were generated or analysed during the current study. Please note: The publisher is not responsible for the content or functionality of any supporting information supplied by the authors. Any queries (other than missing content) should be directed to the corresponding author for the article.
更多
查看译文
关键词
transthoracic echocardiography,equine patients
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要