Vulnerability Analysis of Critical Points in Three-Hinged Arch and Tie Connection
Journal of The Institution of Engineers (India): Series A(2023)
摘要
The codal guidelines for the design of civil engineering structures are mostly based on the overall design of the structure with limited formula-based guidelines to consider the effect of stress concentration. In this study, two vulnerable, isolated infrastructures, namely a three-hinged arch and a tie connection, are modeled and analyzed using ABAQUS. The cross sections of the members originally designed as per IS 456 (2000) for a nominal load of 100kN are re-run for increased loads without increasing the cross-sectional dimensions of the members (but changing other parameters that increase the load-carrying capacity). It is observed that the reinforcement at the crown hinge portion of the three-hinged arch and the notch connecting the members for the tie connection increase in vulnerability for increasing loads and even exceeds the limits of linear analysis, which a civil engineering structure should typically not exceed. The study results are used to arrive at guidelines to be considered for the design of structures.
更多查看译文
关键词
Finite element analysis, Stress analysis, Stress concentration, Three-hinged arch, Tie connection
AI 理解论文