Diastolic delta best predicts paravalvular regurgitation after transcatheter aortic valve replacement as assessed by cardiac magnetic resonance: the APPOSE trial.
European heart journal. Cardiovascular Imaging(2023)
摘要
DD measured during TAVR best predicts relevant PVR. Correction for heart rate (HR-DD) or systolic blood pressure (ARI, ARI ratio) did not improve this predictive value.
更多查看译文
关键词
aortic stenosis,cardiac magnetic resonance,outcomes,paravalvular regurgitation,transcatheter aortic valve replacement