Mobile Technology in Medicine: Development and Validation of an Adapted System Usability Scale (SUS) Questionnaire and Modified Technology Acceptance Model (TAM) to Evaluate User Experience and Acceptability of a Mobile Application in MRI Safety Screening.

Wai-Hun Cheah,Norhasiza Mat Jusoh,Myat Moe Thwe Aung, Azizah Ab Ghani, Husbani Mohd Amin Rebuan

The Indian journal of radiology & imaging(2023)

Cited 0|Views0
No score
Abstract
 Magnetic resonance imaging (MRI) safety screening is a crucial procedure for patient preparation before entering into MRI room. Many hospitals in Malaysia are still using the MRI safety checklist printed form. Besides, clinicians will not get a definite conclusion about whether the patient is contraindicated for MRI or not. Hence, we have created one mobile application named MagnetoSafe to overcome this issue. The application will provide an instant decision on whether the patient has no contraindication, relative contraindication, or absolute contraindicated for MRI. We need to check for acceptability and user experience for any newly created mobile application.  This study was designed to check the validity of the adapted Technology Acceptance Model (TAM) and System Usability Scale (SUS) Questionnaire.  The validity and reliability of the questionnaire were investigated. Subsequently, 52 fully completed responses were collected.  Face and content validity of the questionnaires are considered acceptable with only minor changes to Item 10 of SUS. The Cronbach's alpha for the SUS questionnaire (10 questions) is -0.49, which is not acceptable. The Cronbach's alpha for TAM questionnaire (3 domains; 14 questions) is acceptable, which is 0.910 for perceived usefulness, 0.843 for perceived ease of use, and 0.915 for intention to use.  Face validity of the adapted SUS and modified TAM questionnaires is acceptable with only minor changes to Item 10 in SUS. Content validity with experts is good. However, the reliability of the SUS questionnaire is not acceptable and therefore adapted SUS will not be used for assessing user experience. The reliability of the modified TAM questionnaire with the original three-factor structure is considered acceptable and can be used to evaluate the user's acceptability of MagnetoSafe.
More
Translated text
Key words
MRI safety,magnetic resonance imaging,mobile application,system usability scale,technology acceptance model
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined