Deep Learning-Based Image Quality Improvement in Digital Positron Emission Tomography for Breast Cancer.

Diagnostics (Basel, Switzerland)(2023)

引用 0|浏览7
暂无评分
摘要
We investigated whether F-fluorodeoxyglucose positron emission tomography (PET)/computed tomography images restored via deep learning (DL) improved image quality and affected axillary lymph node (ALN) metastasis diagnosis in patients with breast cancer. Using a five-point scale, two readers compared the image quality of DL-PET and conventional PET (cPET) in 53 consecutive patients from September 2020 to October 2021. Visually analyzed ipsilateral ALNs were rated on a three-point scale. The standard uptake values SUV and SUV were calculated for breast cancer regions of interest. For "depiction of primary lesion", reader 2 scored DL-PET significantly higher than cPET. For "noise", "clarity of mammary gland", and "overall image quality", both readers scored DL-PET significantly higher than cPET. The SUV and SUV for primary lesions and normal breasts were significantly higher in DL-PET than in cPET ( < 0.001). Considering the ALN metastasis scores 1 and 2 as negative and 3 as positive, the McNemar test revealed no significant difference between cPET and DL-PET scores for either reader ( 0.250, 0.625). DL-PET improved visual image quality for breast cancer compared with cPET. SUV and SUV were significantly higher in DL-PET than in cPET. DL-PET and cPET exhibited comparable diagnostic abilities for ALN metastasis.