Can Intrapartum Ultrasonography Improve the Placement of the Vacuum Cup in Operative Vaginal Deliveries?

Tomography(2023)

引用 1|浏览8
暂无评分
摘要
Although the fetal head position has traditionally been evaluated by digital examination (DE), it has a failure rate ranging between 20 and 70%; hence, intrapartum transabdominal ultrasonography (TUS) has become relevant. We aimed to evaluate the utility of the TUS to identify the fetal head positions in vacuum-assisted deliveries. We performed a prospective observational study including 101 pregnant patients in active labor who required a vacuum-assisted delivery. The fetal head position was assessed by a DE and a TUS prior to vacuum cup placement. After delivery, the optimal vacuum cup placement was evaluated as the distance between the chignon and the flexion point ≤2 cm. The general concordance rate between the DE and TUS was 72.2%, with the poorest concordance rate for occiput posterior positions at 46.1%. In five cases (4.9%), it was not possible to determine the fetal head position through the DE. The correlation was higher in low and medium planes, with 77% and 68.1% concordance rates, respectively, while it was lower in high planes (60%). In 90.1% of cases, the vacuum cup placement was optimal. Our findings show that intrapartum transabdominal ultrasonography is a useful technique to identify the fetal head position allowing optimal placement of the vacuum cup necessary for correct vacuum-assisted delivery.
更多
查看译文
关键词
fetal head position,intrapartum ultrasonography,operative vaginal delivery,transabdominal intrapartum ultrasound,transperineal ultrasound,vacuum-assisted delivery