Pre-Operative Four Dimensional Flow Sensitive Magnetic Resonance Imaging Assessment of Aortic Side Branches as a Method to Predict Risk of Type II Endoleak Resulting in Sac Enlargement After EVAR.

European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery(2023)

引用 4|浏览12
暂无评分
摘要
OBJECTIVE:To predict sac enlargement with type II endoleak (ELII) before endovascular aneurysm repair (EVAR) using four dimensional flow sensitive magnetic resonance imaging (4D flow MRI). METHODS:A single centre retrospective analysis of prospectively collected data was conducted. Patients with an abdominal aortic aneurysm (AAA) who underwent EVAR between 2013 and 2019 were included. Aortic branches occluded pre-EVAR, and patients with endoleaks other than ELII were excluded. The aortic branch diameter, peak flow velocity (PFVe), and amplitude of the dynamics of flow volume (AFV) were measured in each aortic branch pre-EVAR. Total flow volume per minute (TFV/min), defined as the sum of AFV/min, was calculated in each case. According to computed tomography findings one year post-EVAR, the aortic branches and patients were divided into patent vessel and occluded vessel groups and sac expanding and non-expanding groups. PFVe, AFV/min, and TFV/min were analysed via receiver operating characteristic curve analysis. RESULTS:The patent aortic branches pre-EVAR (69 inferior mesenteric arteries [IMAs]; 249 lumbar arteries [LAs]) of 100 patients were included. Patent IMAs (n = 14) and occluded IMAs (n = 55), patent LAs (n = 23) and occluded LAs (n = 226), and expanding (n = 9) and non-expanding (n = 91) groups were compared, respectively. No statistically significant difference was observed in branch diameters (IMA; patent, 2.5 ± 0.8 mm, occluded, 2.5 ± 0.8 mm, p < .78 and LA; patent, 1.5 ± 0.3 mm, occluded, 1.5 ± 0.4 mm, p < .35). PFVe (IMA; patent, 262.6 mm2/sec, occluded, 183.4 mm2/sec and LA; patent, 142.6 mm2/sec, occluded, 47.7 mm2/sec) and AFV/min (IMA; patent, 8.4 mL, occluded, 5.2 mL and LA; patent, 4.2 mL, occluded, 1.4 mL) were higher in the patent vessel group (p < .050). TFV/min was statistically significantly higher in the expanding group (24.1 mL/min) than in the non-expanding group (7.0 mL/min) (p < .010). CONCLUSION:Pre-EVAR haemodynamic analyses using 4D flow MRI were useful to detect aortic branches responsible for ELII and to predict AAA cases with sac enlargement. This analysis suggests a new strategy for pre-EVAR aortic branch embolisation.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要