Research on Self-Noise Characteristics of Nine Types of Seismometers Obtained by PDF Representation Using Continuous Seismic Data from the Malingshan Seismic Station, China.

Kaiming Wang, Wenyi Li, Lijun Zhao,Daxin Yu, Shaogang Wei

Sensors(2023)

Cited 0|Views8
No score
Abstract
The self-noise level of a seismometer can determine the performance of the seismic instrument and limit the ability to use seismic data to solve geoscience problems. Accurately measuring and simultaneously comparing the self-noise models from different types of seismometers has long been a challenging task due to the constraints of observation conditions. In this paper, the self-noise power spectral density (PSD) values of nine types of seismometers are calculated using four months of continuous seismic waveforms from Malingshan seismic station, China, and nine self-noise models are obtained based on the probability density function (PDF) representation. For the seismometer STS-2.5, the self-noise levels on the horizontal channels (E-W and N-S) are significantly higher than that on the vertical channel (U-D) in the microseism band (0.1 Hz to 1 Hz), which is a computing bias caused by the misalignment between the sensors in the horizontal direction, while the remarkably elevated noise on the horizontal channels at the low frequencies (<0.6 Hz) may originate from the local variation of atmospheric pressure. As for the very broadband seismometers Trillium-Horizon-120 and Trillium-120PA, and the ultra-broadband seismometers Trillium-Horizon-360 and CMG-3T-360, there is a trade-off between the microseism band range and low-frequency range in the PSD curves of the vertical channel. When the level of self-noise in the microseism band is high, the self-noise at low frequencies is relatively low. Although compared with the other very broadband seismometers, the self-noise level of the vertical component of the STS-2.5 is 3 dB to 4 dB lower at frequencies less than 1 Hz, the self-noise level of the STS-2.5 at high frequencies (>2 Hz) is slightly higher than others. From our observations, we conclude that the nine seismometers cannot reach the lowest noise level in all frequency bands within the working range.
More
Translated text
Key words
coherence analysis,microseism band,power spectral density,probability density function,seismometer,self-noise
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined