Comparisons among the Ultrasonography Prediction Model, Real-Time and Shear Wave Elastography in the Evaluation of Major Salivary Gland Tumors

DIAGNOSTICS(2022)

引用 1|浏览2
暂无评分
摘要
We aimed to validate the diagnostic accuracy of a novel sonographic scoring model and compare it with other methods in the evaluation of malignant major salivary gland tumors. We enrolled 138 patients who received neck ultrasound (US) with fine needle aspiration (FNA) and further operations or core needle biopsies for major salivary gland tumors from June 2015 to October 2021. The sonographic scoring model was presented as 2.08 x (vague boundary) + 1.75 x (regional lymphadenopathy) + 1.18 x (irregular or speculated shape) + 1.45 x (absence of posterior acoustic enhancement) + 2.4 x (calcification). We compared the diagnostic accuracy of the sonographic scoring model with shear wave elastography (SWE), real-time elastography (RTE), and US-FNA cytology for differentiating between benign and malignant lesions. The sensitivity, specificity, and accuracy were 58%, 89%, and 85% for the sonographic scoring model, 74%, 62%, and 64% for the SD of SWE with optimal cutoff value of 31.5 kPa, 69%, 70%, and 70% for the 4-point scoring system of RTE, and 74%, 93%, and 91% for US-FNA cytology, respectively. The sonographic scoring model is feasible as assistance in the evaluation of major salivary gland tumors. US-FNA cytology remains the tool of choice in diagnosing malignant salivary gland tumors.
更多
查看译文
关键词
major salivary gland tumor, ultrasonography, shear wave elastography, real-time elastography, ultrasound-guided fine needle aspiration