Study on Calculation Method of Inlet Steam Flow of External Steam Cooler in Feedwater Heating System

E3S Web of Conferences(2022)

Cited 0|Views2
No score
Abstract
In order to improve the thermal economic performance of coal-fired units in thermal power industry, supercritical units above 600MW generally adopt the method of installing external steam cooler system to improve the utilization of reheat. In view of the difficulties and problems in calculating the three extraction flow of the external steam cooler high pressure heater system by the traditional method, In this paper, a new calculation method of medium flow at the inlet of external steam cooler is proposed based on medium fluid dynamics. This method does not need to install a measuring device, the treatment method is simple and clear, and improves the test efficiency while saving the cost.
More
Translated text
Key words
inlet steam flow,external steam cooler,calculation method