In order to study the hydraulic performance and internal flow field of dual pumps in centrifugal prefabricated pumping station under operation conditions, this paper carried out a numerical calculation based on CFD software for dual pumps in a centrifugal prefabricated pumping station under different flow conditions and verified the internal flow field through test. The results show that the efficiency of centrifugal prefabricated pumping station under design conditions (Q(d) = 33.93 m(3) /h) is 63.96%, the head is 8.66 m, the head at the starting point of the saddle area is 10.50 m, which is 1.21 times of the designed head. The efficiency of the high-efficiency zone of the prefabricated pump station is 58.0 similar to 63.0%, and the corresponding flow range is 0.62Q(d)similar to 1.41Q(d) (21.0 similar to 48.0 m(3)/h). The uniformity of the inlet flow rate of impeller of pump 1 is 74.70%, and that of pump 2 is 75.57%. The flow fields of water pumps on both sides are inconsistent. The results of the flow field indicate that there are severe back flow phenomena at the prefabricated bucket intake, more back flow in the bucket, and many eddies on the side wall. With the increase in flow rate, the eddy structure at the intake expands continuously and moves towards the center area, which has a negative impact on the flow field in the center area. The research results of this paper can provide a theoretical reference for the research and operation of the same type of prefabricated pumping stations.
更多
查看译文
关键词
prefabricated pumping station,centrifugal pump,energy characteristics,internal flow field,test
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要