Roughness correction method for the measurement of attenuation coefficient using contact transducers

INSIGHT(2022)

引用 0|浏览0
暂无评分
摘要
The surface quality of a material significantly affects the accurate measurement of the ultrasonic attenuation coefficient. In this research, a roughness correction method for experimental calculation of the attenuation coefficient using contact transducers is proposed. Firstly, the losses due to the scattering from a rough interface are analysed. According to the mechanism of ultrasonic waves reflected from a thin layer between two solid media, the frequency-dependent reflection coefficient of the coupling interface involving a roughness parameter is derived based on the phase-screen approximation theory. Then, a compensation model is established to correct the error caused by the surface roughness. 304 stainless steel and 45 steel specimens with different levels of surface roughness are prepared and ultrasonic measurements are implemented using both the through-transmission and pulse-echo methods. The experimental results show that the proposed correction method can effectively eliminate the losses caused by surface roughness and improve the measurement accuracy of the attenuation coefficient.
更多
查看译文
关键词
surface roughness, scattering loss, attenuation coefficient, reflection coefficient, contact ultrasonic transducer