Chrome Extension
WeChat Mini Program
Use on ChatGLM

Research on the Relationship Between Meckel's Cavity Shape, Balloon Shape, and Intracapsular Pressure During Percutaneous Balloon Compression

Jianwei Shi, Fuduo Bo, Ruihan Pan, Yansong Zhang,Yang Xu, Hairong Chen, Honglin Ge, Xianwen Cao, Yan Xia,Zhengxiang Luo

World neurosurgery(2022)

Cited 0|Views6
No score
Abstract
- OBJECTIVE: Percutaneous balloon compression is asafe, effective, and minimally invasive therapeutic method for trigeminal neuralgia. Intraoperatively precise compression after the formation of the pear-shaped balloon is the key to the expected effect. In this study, we assessed the relationship between the structure of Meckel's cavity and the shape and intracapsular pressure of the balloon by preoperative magnetic resonance. - METHODS: We respectively analyzed 58 patients with typical trigeminal neuralgia who underwent percutaneous balloon compression surgery in our department. Reconstruction of magnetic resonance imaging 3-dimensional fast imaging employing steady-state acquisition thin-layer scanning sequence was also performed before the operation to analyze the sagittal features of Meckel's cavity. The pressure was recorded continuously when a pear-shaped balloon was forming during the operation. Meanwhile, the balloon height/length (h/l) ratio was measured. The relationship between Meckel's cavity shape, balloon shape, and pressure was analyzed by mentioned parameters. - RESULTS: The pain of 57 patients was relieved immediately after the operation, and the effective rate was 98.27% (57 of 58); Recurrence in 2 cases within the median follow-up time (7.5 months). Meckel's cavity classification on magnetic resonance showed that the clubbing type, oval type, and flat type accounted for 31.1% (18 of 58), 58.6% (34 of 58), and 10.3% (6 of 58), respectively. The results demonstrated that the intracapsular pressure was low, while the h/l ratio of Meckel's cavity was relatively high. We also found the corresponding pressure results when the ratio was low. However, no significant difference was found between the balloon h/l ratio and Meckel's cavity h/l ratio. - CONCLUSIONS: Intracapsular pressure of balloon is negatively correlated with the h/l ratio of Meckel's cavity. The individually differentiated formation of the pear-shaped balloon has little correlation with the sagittal shape of Meckel's cavity.
More
Translated text
Key words
Meckel's cavity,Pear-shaped balloon,Percutaneous balloon compression,Trigeminal neuralgia
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined