谷歌Chrome浏览器插件
订阅小程序
在清言上使用

Study on Coupling Characteristics and Parameter Optimization of Thermoelectric Generation Via Radiative Cooling (Rc-Te) System

SSRN Electronic Journal(2022)

引用 1|浏览1
暂无评分
摘要
Combining radiative cooling (RC) with Thermoelectric (TE) generators to realize passive power generation has been considered to be one of the potential green energy sources, which can achieve the effect of low temperature power generation without the input of external energy. Although some theoretical and experiments have proved that TE can obtain energy from radiative cooling, the realized power density is very low. That is because the limited temperature difference between the two ends of the TE devices caused by the low energy density of the RC significantly reduces the output performance. In addition, the calculation model in the existing research is often simplified, and the influence of complex structure on the energy absorption of the system cannot be accurately considered. Therefore, this paper presents a detailed three-dimensional study on the effect of the structure and configuration of the RC-TE system, and the influence of environmental factors on the performance of the RC-TE. Here, we built a three-dimensional finite element model of a RC-TE system in COMSOL. The three different heat transfer boundaries model were established on the surface of RC to numerically study the per-formance of the RC-TE devices. The influence of RC-TE structure and surrounding environmental parameters on the performance of RC-TE is comprehensively explored, including radiative area ratio, wind speed, ambient temperature, and triethylene glycol structure parameters beta. The results show that when the radiative area ratio is about 33.18, the maximum voltage of RC-TE can be 234.5 mV under ideal conditions. However, compared with the ideal condition, the output performance under the semi-ideal condition and the convection condition is reduced by 66.62% and 86.63%, respectively. As ambient temperature rises from 0 degrees C to 30 degrees C, the maximum voltage is ideal condition about 210.63 mV, while convection condition has greater increase about 49.79 %. As the TE structure beta increases, the output performance is significantly weakened and the rate of reduction gets bigger. The purpose of this study is to analyze, verify, simulate and optimize the prototype radiation cooled thermoelectric generator (RC-TE) model to improve efficiency. These findings will have an important positive impact on the optimal design and practical application of RC-TE.
更多
查看译文
关键词
cooling,coupling characteristics
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要